Lipoxin A4 ELISA Kit
Lipoxin A4 ELISA Kit - 96 well
Nº de SKU 407010 | Número de catálogo
- Highly sensitive
- Results in less than two hours
- Accurate and easy to use
| Especificações | ||
|---|---|---|
| Marca | Neogen® | |
| Tipo de amostra | Lipoxina A4 | |
| Aplicação | Urina, Fluidos orais, Sobrenadante de cultura de tecidos, Plasma, Soro | |
| Assay Range | 0.02 - 2 ng/mL | |
| Uso pretendido | For the determination of Lipoxin A4 in urine, oral fluid, tissue culture supernatant, plasma, or serum samples. Contact a Neogen representative for information on other matrices. | |
| Espécies | Planta | |
| Assay Sample Size | 50 µL | |
| Plataforma | ELISA | |
| Tipo de resultado | Quantitativo | |
| Tamanho da microplaca | 96 well microplate | |
| Tempo total de incubação do ensaio | 90 minutes | |
| Painel de drogas | Especialidade | |
| Condições de armazenamento |
-20°C for lyophilized conjugate, 2-8°C for all other kit components |
|
| Comprimento de onda | 650 nm or 450 nm with acid stop | |
| Peso da embalagem | 0,70 libra | |
Reatividade cruzada
Materiais fornecidos
Materiais necessários, mas não fornecidos
Informações adicionais
Calculation of Results
Neogen has partnered with MyAssays.com to provide an online tool for data calculations.
Follow the simple step-by-step guide to generate your data.
MyAssays.com is a service of MyAssays Ltd. For questions or concerns about the service, please contact MyAssays Ltd.
Documentos
Para acessar o Certificado de Análise (C de A), use nossa Pesquisa de C de A.
Folheto de Instruções
Ficha com Dados de Segurança (FDS)
Tecnologia
The sample or standard solution is first added to the microplate. Next, the diluted enzyme conjugate is added, and the mixture is shaken and incubated at room temperature for one hour. During the incubation, competition for binding sites is taking place. The plate is then washed removing all the unbound material. The bound enzyme conjugate is detected by the addition of substrate which generates an optimal color after 30 minutes. Quantitative test results may be obtained by measuring and comparing the absorbance reading of the wells of the samples against the standards with a microplate reader at 650 nm. The extent of color development is inversely proportional to the amount of Lipoxin A4 in the sample or standard. For example, the absence of Lipoxin A4 in the sample will result in a bright blue color, whereas the presence of Lipoxin A4 will result in decreased or no color development.
Treinamento
Our customers’ success is our shared success. Our experts are ready to train you and your team on our solutions, so you can rest easy knowing procedures are performed properly and yield accurate results. In addition, we provide certificates upon completion of training.