Cortisol ELISA Kit
Cortisol ELISA Kit - 96 well
SKU No. 402710 | Número de catálogo
- Highly sensitive
- Results in less than two hours
- Accurate and easy to use
| Especificaciones | ||
|---|---|---|
| Marca | Neogen® | |
| Analito | Cortisol | |
| Aplicación | Orina, Fluidos orales, Cultivo de tejido sobrenadante, Plasma, Suero | |
| Assay Range | 0.04 - 10 ng/mL | |
| Uso previsto | For the determination of Cortisol in urine, oral fluid, tissue culture supernatant, plasma, or serum samples. Contact a Neogen representative for information on other matrices. | |
| Especies | Específico de especies introducidas | |
| Assay Sample Size | 50 µL | |
| Plataforma | ELISA | |
| Tipo de resultado | Cuantitativo | |
| Tamaño de microplaca | 96 well microplate | |
| Tiempo total de incubación del ensayo | 90 minutes | |
| Grupo de fármacos | Hormonas y esteroides | |
| Condiciones de almacenamiento |
2-8°C |
|
| Longitud de onda | 650 nm or 450 nm with acid stop | |
| Peso del paquete | 0,70 libra | |
Reactividad cruzada
Materiales incluidos
Materiales necesarios, pero no incluidos
Información adicional
Calculation of Results
Neogen has partnered with MyAssays.com to provide an online tool for data calculations.
Follow the simple step-by-step guide to generate your data.
MyAssays.com is a service of MyAssays Ltd. For questions or concerns about the service, please contact MyAssays Ltd.
Documentos
Para acceder al Certificado de Análisis (C de A), use nuestro buscador de C de A.
Inserto
Ficha de datos de seguridad (SDS)
Tecnología
The sample or standard solution is first added to the microplate. Next, the diluted enzyme conjugate is added, and the mixture is shaken and incubated at room temperature for one hour. During the incubation, competition for binding sites is taking place. The plate is then washed removing all the unbound material. The bound enzyme conjugate is detected by the addition of substrate which generates an optimal color after 30 minutes. Quantitative test results may be obtained by measuring and comparing the absorbance reading of the wells of the samples against the standards with a microplate reader at 650 nm. The extent of color development is inversely proportional to the amount of Cortisol in the sample or standard. For example, the absence of Cortisol in the sample will result in a bright blue color, whereas the presence of Cortisol will result in decreased or no color development.