Megazyme® Glycerol GK Assay Kit
70 assays (manual) / 700 assays (microplate) / 600 assays (auto-analyser)
SKU No. 700004293 | Catalog No. K-GCROLGK
- Extended cofactors stability. Dissolved cofactors stable for > 1 year at 4°C.
- Novel tablet format for increased stability
- Very competitive price (cost per test)
- All reagents stable for > 2 years as supplied
- Very rapid reaction
- Positive reaction (assay proceeds with an increase in absorbance)
- Mega-Calc™ software tool is available from our website for hassle-free raw data processing
- Standard included
- Suitable for manual, microplate and auto-analyser formats
Qty:
Minimum quantity required: 1
This item must be ordered in multiples of one case. Quantity per case: 1
| Specifications | ||
|---|---|---|
| Brand | Megazyme® | |
| Analyte | Glycerol | |
| Platform | Spectrophotometer, Microplate, Auto-analyser | |
| Result Type | UV Absorbance | |
| Approvals | Novel method | |
| Limit of Detection | 0.37 mg/L | |
| Storage Conditions | Storage Temperature: Short term stability: 2-8°C, Long term stability: See individual component labels Stability: > 2 years under recommended storage conditions | |
| Wavelength | 340 nm | |
| Application Examples | Wine (and grape juice), beer, spirits, vinegar, marzipan, fruit juices, soft drinks, toothpaste, honey, tobacco, paper (and cardboard), cosmetics, pharmaceuticals, soap and other materials (e.g. biological cultures, samples, etc.). | |
| Signal Response | Increase | |
| Linear Range | 1.0 to 35 μg of glycerol per assay | |
| Reaction Time | ~ 7 min | |
| Package Dimensions | 10.00 in x 5.00 in x 2.00 in | |
| Package Weight | 0.49 lb | |
Documents