Neogen® Molecular Detection Assay 2, E. coli O157 (including H7)

MDA2 E. coli; MDA2 O157:H7

SKU No.  700002229  |  Catalog No.  MDA2ECO96

  • One post-enrichment assay protocol and fewer steps than most tests reduces repetitive tasks and makes it easy to train employees.
  • Ready-to-use and pre-dispensed reagents provide convenience and minimize the chance of human error.
  • Color-coded assay tubes by organism and matching software screens allow for better tracking and easy identification.
  • The ability to run all assays simultaneously and the flexibility to test up to 96 samples in each run helps you operate more efficiently.
  • Real-time amplification and detection process identifies positive results in as early as 15 minutes and allows you to make critical decisions faster.
Qty:
Minimum quantity required: 1
This item must be ordered in multiples of one case. Quantity per case: 1
As with all test methods, the source, formulation and quality of enrichment medium can influence the results. Neogen® has evaluated the Neogen® Molecular Detection Assay 2 - E. coli O157 (including H7) with Buffered Peptone Water ISO.
Specifications
BrandNeogen® Molecular Detection System
AnalyteE. coli O157
PlatformMolecular Detection System
Result TypeQualitative
ApprovalsAOAC® Official Method of Analysis℠ 2017.01, NF Validation by AFNOR, certificate 3M 01/18-05/17
Limit of Detection1 Colony Forming Unit (CFU) per portion
Time to Result9.6 - 25.6 Hours
Storage Conditions2-8°C | Do not freeze
Case Count1
Quantity per Package96 tests
Package Dimensions18.50 cm x 12.80 cm x 8.30 cm
Package Weight0.75 lb
  1. 96 Lysis Solution (LS)
  2. 96 Molecular Detection Assay 2 - E. coli O157 (including H7) Reagent Tubes
  3. 96 Extra caps
  4. 16 Reagent Control (RC)
  1. Neogen® Molecular Detection Instrument and Accessory Kit (Neogen item: 700002195|MDS100)
  2. Neogen® Molecular Detection Matrix Control (Neogen item: 700002079|MDMC96NA)
  3. Neogen® Molecular Detection Cap/Decap Tool - Lysis (Neogen item: 700000142|MDSCDL)
  4. Neogen® Molecular Detection Cap/Decap Tool - Reagent (Neogen item: 700000141|MDSCDR)
  5. Neogen® Molecular Detection Heat/Chill Block Insert (Neogen item: 700000145|MDSHBIN)

Technology

Powered by an innovative combination of unique technologies to bring molecular level accuracy expected by customers – without sacrificing productivity.

The Molecular Detection System use Loop-Mediated Isothermal Amplification (LAMP) to amplify specific regions of the DNA with high sensitivity and specificity.

Training

Our customers’ success is our shared success. Our experts are ready to train you and your team on our solutions, so you can rest easy knowing procedures are performed properly and yield accurate results. In addition, we provide certificates upon completion of training to provide you with the documentation needed for audit traceability.