Reveal® 3-D for Hazelnut

SKU No.  700002646  |  Catalog No.  902087E

  • Results in just 5 minutes
  • Easy-to-use lateral flow test strip — no equipment needed
Qty:
Minimum quantity required: 1
This item must be ordered in multiples of one case. Quantity per case: 1
Reveal® 3-D for Hazelnut offers results in just 5 minutes and can be used in virtually any environment to screen environmental swabs and clean-in-place rinses. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against oversaturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline nondetectable, low, and high levels of hazelnut.
Specifications
BrandReveal®
AnalyteHazelnut, Tree Nuts
PlatformLateral Flow
Result TypeQualitative
Limit of DetectionScreens samples at 0.75-1.5 ppm hazelnut protein (5-10 ppm total hazelnut). Screens samples at 10 µg/100 cm2 hazelnut.
Testing Time5.00
Quantity per Package10 tests
Package Dimensions9.75 in x 6.75 in x 1.50 in
Package Weight0.50 lb

The Reveal 3-D for Hazelnut test pack contains the following:

  1. 1 foil pouch, containing 10 blue Reveal 3-D for Hazelnut devices
  2. 10 sachets containing Type 11 Extraction Buffer
  3. 10 sample tubes and caps
  4. 10 individually packaged, sterile swabs with break-off tips
  5. 1 bottle of swab wetting solution

The extraction of food samples requires the following:

  1. 3-D Food Buffer (Item Number 8504)
  2. Graduated 50 mL polypropylene test tubes (Item Number 9381)

Documents

To access certificates, please use our technical document search page.

Reveal® 3-D for Hazelnut - English - US Reveal® 3-D for Hazelnut - Vietnamese - Vietnam Reveal® 3-D for Hazelnut - Croatian - Croatia Reveal® 3-D for Hazelnut - Japanese - Japan Reveal® 3-D for Hazelnut - English - New Zealand Reveal® 3-D for Hazelnut - Chinese Traditional - Taiwan Reveal® 3-D for Hazelnut - Danish - Denmark Reveal® 3-D for Hazelnut - Lithuanian - Lithuania Reveal® 3-D for Hazelnut - Czech - Czech Republic Reveal® 3-D for Hazelnut - Chinese Simplified - China Reveal® 3-D for Hazelnut - Swedish - Sweden Reveal® 3-D for Hazelnut - Bulgarian - Bulgaria Reveal® 3-D for Hazelnut - Portuguese - Portugal Reveal® 3-D for Hazelnut - German Reveal® 3-D for Hazelnut - English - EU/UK Reveal® 3-D for Hazelnut - Greek - Cyprus Reveal® 3-D for Hazelnut - English - Ireland Reveal® 3-D for Hazelnut - Finnish - Finland Reveal® 3-D for Hazelnut - French - Belgium Reveal® 3-D for Hazelnut - Slovene - Slovenia Reveal® 3-D for Hazelnut - Dutch - Belgium Reveal® 3-D for Hazelnut - Spanish - Colombia Reveal® 3-D for Hazelnut - Indonesian - Indonesia Reveal® 3-D for Hazelnut - Malay - Malaysia Reveal® 3-D for Hazelnut - Korean - Korea Reveal® 3-D for Hazelnut - Dutch - Netherlands Reveal® 3-D for Hazelnut - German - Luxembourg Reveal® 3-D for Hazelnut - Spanish - US Reveal® 3-D for Hazelnut - Spanish - Mexico Reveal® 3-D for Hazelnut - Latvian - Latvia Reveal® 3-D for Hazelnut - English - Canada Reveal® 3-D for Hazelnut - English - Philippines Reveal® 3-D for Hazelnut - Norwegian - Norway Reveal® 3-D for Hazelnut - French Reveal® 3-D for Hazelnut - English - Malta Reveal® 3-D for Hazelnut - Slovak - Slovakia Reveal® 3-D for Hazelnut - English - Australia Reveal® 3-D for Hazelnut - German - Austria Reveal® 3-D for Hazelnut - Thai - Thailand Reveal® 3-D for Hazelnut - Greek - Greece Reveal® 3-D for Hazelnut - Spanish - Spain Reveal® 3-D for Hazelnut - Portuguese - Brazil Reveal® 3-D for Hazelnut - French - Canada Reveal® 3-D for Hazelnut - Polish - Poland Reveal® 3-D for Hazelnut - Estonian - Estonia Reveal® 3-D for Hazelnut - Hungarian - Hungary Reveal® 3-D for Hazelnut - Maltese - Malta Reveal® 3-D for Hazelnut - Italian - Italy

Technology

Assay Principles

The Reveal 3-D format is a single-step lateral flow immunochromatographic assay. The extract is wicked through a reagent zone, which con­tains antibodies specific for the target allergen conjugated to colored particles. If allergen is present, it will be captured by the conjugated antibodies. The allergen antibody-particle complex then is wicked onto a membrane which contains a zone of antibody specific for the target allergen. This zone captures the complex allowing the particles to concentrate and form a visible line. If no target allergen is present, no line will form.

Training

Our customers’ success is our shared success. Our experts are ready to train you and your team on our solutions, so you can rest easy knowing procedures are performed properly and yield accurate results. In addition, we provide certificates upon completion of training to provide you with the documentation needed for audit traceability.

Support

Validation

Our experts are here to help. If you need information beyond what is provided in Validation Reports under the Documents tab, please contact us and we will be happy to assist you. Learn more