ISO-GRID® & NEO-GRID®
Item No. 6802
Specifications | |
---|---|
Analyte | E. coli O157, Coliforms, E. coli, Listeria, Listeria monocytogenes, Salmonella, Total Plate Count, Yeast & Mould |
Approvals |
ISO-GRID/NEO-GRID Method Approvals Yeast and Mold Count AOAC No. 995.21 Canadian Compendium of Analytical Methods-Health Canada Enumeration of coliforms in foods by the hydrophobic grid membrane filter method. MFHPB-17 Canadian Standard Methods for the Examination of Water and Wastewater Standard total coliform membrane filter procedure 9222B |
Brand | ISO-GRID® |
Package Dimensions | 4.10 IN x 4.00 IN x 1.70 IN |
Package Weight | 0.20 LB |
Quantity per Package | 100 filters |
Additional Information
Culture Media
Product # | Product Description |
6903A | BMA Agar – For the confirmation of E. coli. |
6901A | EF-18 Agar – For detecting and confirming Salmonella. |
6913A | LM-137 Agar – For the presumptive enumeration of Listeria and Listeria monocytogenes. |
6902A | LMG Agar – For the detection of coliforms. |
6910A | SCCRAM Broth – For the enrichment of Salmonella. |
6907A | SD-39 Agar – For the enumeration of E. coli and E. coli O157:H7. |
6905A | TSAF Agar – Used to determine total bacterial counts. |
6904A | YM-11 Agar – For the enumeration of yeasts and molds in only 48 hours. |
Enyzmes
Enzymes are used to digest the food commodities so that they can pass through the 0.45 µm membrane. The following enzymes are available:
Product # | Product Description |
6852E | AMG – For the digestion of starchy foods. |
6851E | APUG – For the digestion of proteinaceous foods. |
6853E | Cellulase – For the digestion of gums. |
6854E | Hemicellulase – For the digestion of gums. |
6850E | Papain – For the digestion of proteinaceous foods. |
Accessories
Product # | Product Description |
6810 | 1-Place Filtration Manifold |
6800 | 3-Place Filtration Manifold |
6801 | 6-Place Filtration Manifold |
6821 | Rubber Tubing (10 feet) |
6822 | Side-Arm Flask Assembly (1 L) |
6824 | Vacuum Pump - ¼ hp (Gast) |
6818 | Vacuum Pump Oil (quart) |
6828 | Forceps |
6812 | Vacuum Tubing Assembly |
6823 | Tubing Clamp |
Technology
Samples are first diluted in a sterile buffer. The ISO-GRID /NEO-GRID filtration unit then is placed onto a manifold connected to a vacuum source, and a sterile filter membrane is placed in the ISO-GRID filtration unit (NEO-GRID already contains a sterile filter membrane). Using the vacuum source, a portion of the diluted sample is filtered through the filter membrane.
The membrane is transferred to an agar plate prepared with a medium formulated to promote/differentiate the growth of the target organism. Following incubation, the plate’s squares containing presumptively positive colonies are counted to yield a most probable number (MPN) result.
Training
Our customers’ success is our shared success. Our experts are ready to train you and your team on our solutions, so you can rest easy knowing procedures are performed properly and yield accurate results. In addition, we provide certificates upon completion of training to provide you with the documentation needed for audit traceability.