Reveal® 3-D for Gluten

Item No.  700002634  |  Catalog No.  901031P

  • Results in just 5 minutes
  • Easy-to-use lateral flow test strip — no equipment needed
This item has shipping restrictions.
$218.88 each
In stock
Out of stock
Expect availability in 2-4 weeks
Qty:
Minimum quantity required: 1
This item must be ordered in multiples of one case. Quantity per case: 1
Reveal® 3-D for Gluten offers results in just 5 minutes and can be used in virtually any environment to screen environmental swabs and clean-in-place rinses. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against oversaturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline nondetectable, low, and high levels of gluten.
Specifications
Brand Reveal®
Analyte Gliadin/Gluten
Platform Lateral Flow
Result Type Qualitative
Limit of Detection Screens samples at 5–10 ppm gluten. Screens swabs at 80 µg/100 cm2 gluten.
Testing Time 5.00
Prop 65 Warning
Warning
WARNING: This product can expose you to chemicals including thimerosal, which is known in the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov
Quantity per Package 10 tests
Package Dimensions 10.00 in x 8.50 in x 8.80 in
Package Weight 0.40 lb

The pack contains the following:

  1. 1 sealed foil pouch, containing 10 green Reveal 3-D for Gluten devices
  2. 1 bottle of swab wetting solution
  3. 10 sachets containing 1 mL of Type 4 Extraction Buffer
  4. 10 sachets containing 3 mL of Type 5 Extraction Buffer
  5. 10 individually packaged, sterile swabs with break-off tips

Documents

To access certificates, please use our technical document search page.

Reveal® 3-D for Gluten - English - US Reveal® 3-D for Gluten - French Reveal® 3-D for Gluten - Bulgarian - Bulgaria Reveal® 3-D for Gluten - Chinese Simplified - China Reveal® 3-D for Gluten - Chinese Traditional - Taiwan Reveal® 3-D for Gluten - Croatian - Croatia Reveal® 3-D for Gluten - Czech - Czech Republic Reveal® 3-D for Gluten - Danish - Denmark Reveal® 3-D for Gluten - Dutch - Belgium Reveal® 3-D for Gluten - Dutch - Netherlands Reveal® 3-D for Gluten - English - Australia Reveal® 3-D for Gluten - English - Canada Reveal® 3-D for Gluten - English - EU/UK Reveal® 3-D for Gluten - English - Ireland Reveal® 3-D for Gluten - English - Malta Reveal® 3-D for Gluten - English - New Zealand Reveal® 3-D for Gluten - English - Philippines Reveal® 3-D for Gluten - Estonian - Estonia Reveal® 3-D for Gluten - Finnish - Finland Reveal® 3-D for Gluten - French - Belgium Reveal® 3-D for Gluten - French - Canada Reveal® 3-D for Gluten - German Reveal® 3-D for Gluten - German - Austria Reveal® 3-D for Gluten - German - Luxembourg Reveal® 3-D for Gluten - Greek - Cyprus Reveal® 3-D for Gluten - Greek - Greece Reveal® 3-D for Gluten - Hungarian - Hungary Reveal® 3-D for Gluten - Indonesian - Indonesia Reveal® 3-D for Gluten - Italian - Italy Reveal® 3-D for Gluten - Japanese - Japan Reveal® 3-D for Gluten - Korean - Korea Reveal® 3-D for Gluten - Latvian - Latvia Reveal® 3-D for Gluten - Lithuanian - Lithuania Reveal® 3-D for Gluten - Malay - Malaysia Reveal® 3-D for Gluten - Maltese - Malta Reveal® 3-D for Gluten - Norwegian - Norway Reveal® 3-D for Gluten - Polish - Poland Reveal® 3-D for Gluten - Portuguese - Brazil Reveal® 3-D for Gluten - Portuguese - Portugal Reveal® 3-D for Gluten - Slovak - Slovakia Reveal® 3-D for Gluten - Slovene - Slovenia Reveal® 3-D for Gluten - Spanish - Colombia Reveal® 3-D for Gluten - Spanish - Mexico Reveal® 3-D for Gluten - Spanish - Spain Reveal® 3-D for Gluten - Spanish - US Reveal® 3-D for Gluten - Swedish - Sweden Reveal® 3-D for Gluten - Thai - Thailand Reveal® 3-D for Gluten - Vietnamese - Vietnam

Technology

Assay Principles

The Reveal 3-D format is a single-step lateral flow immunochromatographic assay. The extract is wicked through a reagent zone, which con­tains antibodies specific for the target allergen conjugated to colored particles. If allergen is present, it will be captured by the conjugated antibodies. The allergen antibody-particle complex then is wicked onto a membrane which contains a zone of antibody specific for the target allergen. This zone captures the complex allowing the particles to concentrate and form a visible line. If no target allergen is present, no line will form.

Training

Our customers’ success is our shared success. Our experts are ready to train you and your team on our solutions, so you can rest easy knowing procedures are performed properly and yield accurate results. In addition, we provide certificates upon completion of training to provide you with the documentation needed for audit traceability.

Support

Validation

Our experts are here to help. If you need information beyond what is provided in Validation Reports under the Documents tab, please contact us and we will be happy to assist you. Learn more