Reveal® 3-D for Coconut

Item No.  700002604  |  Catalog No.  8565

  • Results in just 5 minutes
  • Easy-to-use lateral flow test strip — no equipment needed
This item has shipping restrictions.
$218.88 each
In stock
Out of stock
Expect availability in 2-4 weeks
Qty:
Minimum quantity required: 1
This item must be ordered in multiples of one case. Quantity per case: 1

Reveal® 3-D for Coconut offers results in just 5 minutes and can be used in virtually any environment to screen for coconut in liquid products (like UHT beverages, juices, drink flavours, etc.), clean-in-place rinses and environmental surfaces. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against over-saturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline non-detectable, low, and high levels of coconut.

Specifications
Brand Reveal®
Analyte Coconut, Tree Nuts
Platform Lateral Flow
Result Type Qualitative
Limit of Detection Screens samples at 1 ppm coconut protein. Screens swabs at 1 μg/100 cm2 coconut protein.
Testing Time 5.00
Quantity per Package 10 tests
Package Dimensions 6.30 in x 3.10 in x 0.10 in
Package Weight 0.50 lb

The Reveal 3-D Coconut Test pack contains the following:

  1. 1 foil pouch, containing 10 white Reveal 3-D for Coconut test devices
  2. 10 sample tubes and caps
  3. 10 sachets of Type 8 extraction buffer
  4. 10 sterile swabs
  5. 1 bottle swab wetting solution

Documents

To access certificates, please use our technical document search page.

Reveal® 3-D for Coconut - English - US Reveal® 3-D for Coconut - Bulgarian - Bulgaria Reveal® 3-D for Coconut - Chinese Simplified - China Reveal® 3-D for Coconut - Chinese Traditional - Taiwan Reveal® 3-D for Coconut - Croatian - Croatia Reveal® 3-D for Coconut - Czech - Czech Republic Reveal® 3-D for Coconut - Danish - Denmark Reveal® 3-D for Coconut - Dutch - Belgium Reveal® 3-D for Coconut - Dutch - Netherlands Reveal® 3-D for Coconut - English - Australia Reveal® 3-D for Coconut - English - Canada Reveal® 3-D for Coconut - English - EU/UK Reveal® 3-D for Coconut - English - Great Britain Reveal® 3-D for Coconut - English - Ireland Reveal® 3-D for Coconut - English - Malta Reveal® 3-D for Coconut - English - New Zealand Reveal® 3-D for Coconut - English - Philippines Reveal® 3-D for Coconut - Estonian - Estonia Reveal® 3-D for Coconut - Finnish - Finland Reveal® 3-D for Coconut - French Reveal® 3-D for Coconut - French - Belgium Reveal® 3-D for Coconut - French - Canada Reveal® 3-D for Coconut - German Reveal® 3-D for Coconut - German - Austria Reveal® 3-D for Coconut - German - Luxembourg Reveal® 3-D for Coconut - Greek - Cyprus Reveal® 3-D for Coconut - Greek - Greece Reveal® 3-D for Coconut - Hungarian - Hungary Reveal® 3-D for Coconut - Indonesian - Indonesia Reveal® 3-D for Coconut - Italian - Italy Reveal® 3-D for Coconut - Japanese - Japan Reveal® 3-D for Coconut - Korean - Korea Reveal® 3-D for Coconut - Latvian - Latvia Reveal® 3-D for Coconut - Lithuanian - Lithuania Reveal® 3-D for Coconut - Malay - Malaysia Reveal® 3-D for Coconut - Maltese - Malta Reveal® 3-D for Coconut - Norwegian - Norway Reveal® 3-D for Coconut - Polish - Poland Reveal® 3-D for Coconut - Portuguese - Brazil Reveal® 3-D for Coconut - Portuguese - Portugal Reveal® 3-D for Coconut - Slovak - Slovakia Reveal® 3-D for Coconut - Slovene - Slovenia Reveal® 3-D for Coconut - Spanish - Colombia Reveal® 3-D for Coconut - Spanish - Mexico Reveal® 3-D for Coconut - Spanish - Mexico/Central America Reveal® 3-D for Coconut - Spanish - Spain Reveal® 3-D for Coconut - Spanish - US Reveal® 3-D for Coconut - Swedish - Sweden Reveal® 3-D for Coconut - Thai - Thailand Reveal® 3-D for Coconut - Vietnamese - Vietnam

Technology

Assay Principles

The Reveal 3-D format is a single-step lateral flow immunochromatographic assay. The extract is wicked through a reagent zone, which con­tains antibodies specific for the target allergen conjugated to colored particles. If allergen is present, it will be captured by the conjugated antibodies. The allergen antibody-particle complex then is wicked onto a membrane which contains a zone of antibody specific for the target allergen. This zone captures the complex allowing the particles to concentrate and form a visible line. If no target allergen is present, no line will form.

Training

Our customers’ success is our shared success. Our experts are ready to train you and your team on our solutions, so you can rest easy knowing procedures are performed properly and yield accurate results. In addition, we provide certificates upon completion of training to provide you with the documentation needed for audit traceability.

Support

Validation

Our experts are here to help. If you need information beyond what is provided in Validation Reports under the Documents tab, please contact us and we will be happy to assist you. Learn more